Search

Marco J Daoura

from Woodinville, WA
Age ~55

Marco Daoura Phones & Addresses

  • Woodinville, WA
  • 17807 31St St, Bothell, WA 98012 (425) 489-8228
  • 3903 City Ave #1203, Philadelphia, PA 19131 (425) 489-8228
  • Mountlake Terrace, WA
  • Snohomish, WA
  • Kirkland, WA

Resumes

Resumes

Marco Daoura Photo 1

Executive Vice President Of Program And Product Management

View page
Location:
17807 31St St, Bothell, WA 98012
Industry:
Medical Devices
Work:
Early Stage Startup
Advisor | Technology and Market

Premera Blue Cross
Innovation Principal Consultant | Digital Health

Ekos Corporation, A Btg International Group Company Sep 2018 - Apr 2019
Principal Consultant | Program and Project Management

Medsien Jun 2018 - Feb 2019
Advisor | Healthcare and Digital Health Strategies

Keiretsu Forum Jun 2018 - Feb 2019
Probono | Technical Committee Co-Chair
Education:
University of Washington
Bachelors, Bachelor of Science In Electrical Engineering, Electrical Engineering
University of Washington
Masters, Biomedical Engineering, Biotechnology, Electrical Engineering, Engineering, Bioengineering
Skills:
Cross Functional Team Leadership
Product Development
Product Management
Medical Devices
Product Launch
Strategy
Product Marketing
Program Management
Medical Imaging
Management
Marketing
Strategic Planning
Product Lifecycle Management
Market Development
Process Improvement
R&D
Six Sigma
Capital Equipment
Sales Management
Business Development
Healthcare
Dicom
Software Development
Business Intelligence
Marketing Strategy
Digital Imaging
Commercialization
Global Marketing
Biomedical Engineering
Competitive Analysis
Entrepreneurship
Segmentation
Customer Service
Analysis
Pacs
Marketing Management
Business Strategy
Customer Relations
Strategic Partnerships
Start Ups
Leadership
Product Service
Hardware Diagnostics
Business Process Improvement
Research and Development
Product Services
Digital Health
Digital Marketing
Cardiology
Research and Development
Project Management
Software As A Service
Agile Methodologies
Languages:
Arabic
French
English
Spanish
Certifications:
Certified Six Sigma Green Belt
Marco Daoura Photo 2

Marco Daoura

View page

Publications

Us Patents

System And Method For Organizing, Recording And Displaying Images In Ultrasound Imaging Systems

View page
US Patent:
20100286524, Nov 11, 2010
Filed:
Jul 6, 2007
Appl. No.:
12/373115
Inventors:
Marco Daoura - Bothell WA, US
Earl Canfield - Snohomish WA, US
Assignee:
KONINKLIJKE PHILIPS ELECTRONICS, N.V. - EINDHOVEN
International Classification:
A61B 8/14
A61B 5/04
US Classification:
600443, 600509
Abstract:
An ultrasound imaging system includes a video processor receiving coherent echo signals from a beamformer. The video processor converts the coherent echo signals to image data, which are applied to a streaming digital video processor. The system also includes an ECG monitor and processor that obtains an ECG signal and uses the signal to provide heart cycle data indicative of the beginning and end of each of the plurality of heart cycles. The streaming digital video processor converts the image data into streaming digital data, which are divided into the heart cycle sections as indicated by the heart cycle data. The system also includes a digital video disk recorder that records a digital video disk containing the digital video data divided into chapters containing respective heart cycle sections. The recorder may also record chapters of ECG data derived from the ECG signal along with the digital video data.

Ultrasound Imaging System With Improved Training Modes

View page
US Patent:
20160351078, Dec 1, 2016
Filed:
May 29, 2015
Appl. No.:
14/725670
Inventors:
- Bothell WA, US
Amanda Mander - Bainbridge Island WA, US
Luke Baldwin - Lake Stevens WA, US
Marco Daoura - Bothell WA, US
International Classification:
G09B 23/28
G09B 5/06
A61B 8/00
Abstract:
An ultrasound imaging system includes a control with which a user can view one or more training materials regarding how to use the system or perform an examination. The training materials are associated with one or more of the operating parameters of the ultrasound system. Upon selecting a help me control, a search is performed for those training materials that are associated with one or more current operating parameters of the ultrasound system. In another aspect, training materials include a record of one or more operating parameters used or described in the content of the training materials. When viewing training material, a user can select a “show me” control on the ultrasound system, which causes the operating parameters used or described in the training material to be loaded into the circuitry of the ultrasound machine. The user can then operate the ultrasound imaging system with the same imaging parameters used or described in the training material being viewed.

Method And Apparatus For Interactive Display Of Three Dimensional Ultrasound Images

View page
US Patent:
20140358002, Dec 4, 2014
Filed:
Dec 20, 2012
Appl. No.:
14/368107
Inventors:
- Eindhoven, NL
Marco J. Daoura - Bothell WA, US
International Classification:
A61B 8/00
A61B 8/08
US Classification:
600443
Abstract:
A medical imaging system comprises a three dimensional (3D) ultrasound system and a 3D holographic display system. The ultrasound system generates 3D ultrasound data that can be used to construct a 3D image of a patient. The display system displays the image in a 3D holographic form and comprises a touchless input interface that allows a user to control the display from within a sterile field while performing a medical procedure.
Marco J Daoura from Woodinville, WA, age ~55 Get Report