Search

Jacob Maniyatte Phones & Addresses

  • 17 Pollari Cir, Newark, DE 19702 (302) 368-0718 (410) 620-4168

Resumes

Resumes

Jacob Maniyatte Photo 1

Engineering Manager - Technology And Solutions Engineering

View page
Location:
Newark, DE
Industry:
Medical Devices
Work:
Agilent Technologies
Engineering Manager - Technology and Solutions Engineering

Siemens Healthcare 2011 - 2018
Staff Systems Engineer

Johnson & Johnson 2006 - 2011
Staff Mechanical Engineer

W. L. Gore & Associates 1997 - 2006
Senior Project Manager

Omron Adept Technologies 1993 - 1997
Software Applications Engineer
Education:
Worcester Polytechnic Institute 1989 - 1993
Bachelor of Science In Mechanical Engineering, Bachelors, Mechanical Engineering
Skills:
Medical Devices
Validation
Design Control
V&V
Fda
Robotics
Iso 13485
Injection Molding
Fmea
Requirements Management
Systems Engineering
Fda Gmp
Cross Functional Team Leadership
Stents
Catheters
Manufacturing Systems
Six Sigma
System Verification
Iso 15288
Incose Certified Systems Engineer
Certifications:
Certified Systems Engineering Professional - Csep
Certified Scrummaster
Jacob Maniyatte Photo 2

Jacob Maniyatte

View page

Publications

Us Patents

Controlled Failure Balloon Catheter Assemblies

View page
US Patent:
20060161102, Jul 20, 2006
Filed:
Jan 18, 2005
Appl. No.:
11/037747
Inventors:
Kenneth Newcomb - Wilmington DE, US
Jacob Maniyatte - Newark DE, US
International Classification:
A61M 29/00
US Classification:
604096010, 606192000, 604099010, 604915000, 604920000
Abstract:
Novel balloon catheter assemblies comprising controlled failure portion that fails at a pressure which will prevent undesired balloon rupture. The controlled failure portion can be located on or in a catheter shaft, a hub assembly, and/or a hub extension piece.

Controlled Failure Balloon Catheter Assemblies

View page
US Patent:
20060264823, Nov 23, 2006
Filed:
Jul 25, 2006
Appl. No.:
11/493691
Inventors:
Kenneth Newcomb - Wilmington DE, US
Jacob Maniyatte - Newark DE, US
International Classification:
A61M 29/00
US Classification:
604099010, 604118000, 604103040
Abstract:
Novel balloon catheter assemblies comprising controlled failure portion that fails at a pressure which will prevent undesired balloon rupture. The controlled failure portion can be located on or in a catheter shaft, a hub assembly, and/or a hub extension piece.

Rigid Multi-Functional Filter Assembly

View page
US Patent:
62384678, May 29, 2001
Filed:
Sep 24, 1999
Appl. No.:
9/405495
Inventors:
Michael H. Azarian - Wallingford PA
Jacob Maniyatte - Elkton MD
Assignee:
Gore Enterprise Holdings, Inc. - Newark DE
International Classification:
B01D 5304
US Classification:
96135
Abstract:
A unitary rigid filter that performs multiple contamination control functions within an enclosure for sensitive equipment (e. g. , disk drives). The filter incorporates recirculation and adsorbent filtration, along with optional inlet and diffusion functions in a unique rigid filter construction.
Jacob J Maniyatte from Newark, DE, age ~53 Get Report